J-Link PLUS V11
This page contains the general, mechanical and electrical specifications of the SEGGER J-Link PLUS V11.
Specifications
Specification | Value |
---|---|
General | |
Supported OS | Microsoft Windows (x86/x64), Linux (x86/x64/Arm), macOS (x86) |
Electromagnetic compatibility (EMC) | EN 55022, EN 55024 |
Operating temperature | +5°C ... +60°C |
Storage temperature | -20°C ... +65 °C |
Relative humidity (non-condensing) | Max. 90% rH |
Mechanical | |
Size (without cables) | 100mm x 53mm x 27mm |
Weight (without cables) | 70g |
Available interfaces | |
USB interface | USB 2.0 (Hi-Speed); USB Type B |
Target interface | JTAG 20-pin (14-pin and other adapters available) |
JTAG/SWD Interface, Electrical | |
Power supply | USB powered Max. 50mA + Target Supply current. |
Target interface voltage (VIF) | 1.2V ... 5V |
Target supply voltage | 5V (derived from USB voltage) |
Target supply current | Max. 300mA |
Reset Type | Open drain. Can be pulled low or tristated. |
Reset low level output voltage (VOL) | VOL <= 10% of VIF |
For the whole target voltage range (1.2V <= VIF <= 5V) | |
LOW level input voltage (VIL) | VIL <= 40% of VIF |
HIGH level input voltage (VIH) | VIH >= 60% of VIF |
For 1.2V <= VIF <= 3.6V | |
LOW level output voltage (VOL) with a load of 10 kOhm | VOL <= 20% of VIF |
HIGH level output voltage (VOH) with a load of 10 kOhm | VOH >= 80% of VIF |
For 3.6 <= VIF <= 5V | |
LOW level output voltage (VOL) with a load of 10 kOhm | VOL <= 20% of VIF |
HIGH level output voltage (VOH) with a load of 10 kOhm | VOH >= 80% of VIF |
JTAG/SWD Interface, Timing | |
Target interface speed | Max. 15 MHz |
SWO sampling frequency | Max. 30 MHz |
Data input rise time (Trdi) | Trdi <= 20ns |
Data input fall time (Tfdi) | Tfdi <= 20ns |
Data output rise time (Trdo) | Trdo <= 10ns |
Data output fall time (Tfdo) | Tfdo <= 10ns |
Clock rise time (Trc) | Trc <= 3ns |
Clock fall time (Tfc) | Tfc <= 3ns |