Tracing on NXP Kinetis MK60N512

From SEGGER Wiki
Revision as of 13:53, 14 February 2017 by Nino (talk | contribs)
Jump to: navigation, search

This article describes how to get started with trace on the NXP Kinetis MK60N512 MCU. This article assumes that there is already a basic knowledge about trace in general (what is trace, what different implementations of trace are there, etc.). If this is not the case, we recommend to read Trace chapter in the J-Link User Manual (UM08001). The NXP Kinetis MK60N512 MCU implements tracing via pins and ETB, so a J-Trace as well as the ETB can be used for tracing. Note: The ETB does not support stream tracing.

Minimum requirements

In order to use trace on the NXP Kinetis MK60N512 MCU devices, the following minimum requirements have to be met:

  • J-Link software version V6.13e (beta) / V6.14 (release) or later
  • Ozone V2.22o or later (if streaming trace and / or the sample project from below shall be used)
  • J-Trace PRO for Cortex-M HW version V1.0 or later

Sample project

Streaming trace

The following sample project is designed to be used with J-Trace PRO and Ozone to demonstrate streaming trace. The project has been tested with the minimum requirements mentioned above. The sample project comes with a pre-configured project file for Ozone that runs out-of-the box. In order to rebuild the sample project, SEGGER Embedded Studio can be used.

ETB trace