Tracing on NXP Kinetis MK64FN1M0

From SEGGER Wiki
Revision as of 12:28, 2 June 2017 by Nino (talk | contribs) (Streaming trace)
Jump to: navigation, search

This article describes how to get started with trace on the NXP Kinetis MK64FN1M0 MCU. This article assumes that there is already a basic knowledge about trace in general (what is trace, what different implementations of trace are there, etc.). If this is not the case, we recommend to read Trace chapter in the J-Link User Manual (UM08001). The NXP Kinetis MK64FN1M0 MCU implements tracing via pins or via on-chip trace buffer (ETB), so a J-Trace as well as the ETB can be used for tracing.

Minimum requirements

In order to use trace on the NXP Kinetis MK64FN1M0 MCU devices, the following minimum requirements have to be met:

  • J-Link software version V6.14a or later
  • Ozone V2.22o or later (if streaming trace and / or the sample project from below shall be used)
  • J-Trace PRO for Cortex-M HW version V1.0 or later

Sample project

Streaming trace

The following sample project is designed to be used with J-Trace PRO and Ozone to demonstrate streaming trace. The project has been tested with the minimum requirements mentioned above and a TWR-K64F120M Evalboard. The sample project comes with a pre-configured project file for Ozone that runs out-of-the box. In order to rebuild the sample project, SEGGER Embedded Studio can be used.

NXP_Kinetis_K64FN1M0_60MHz_TraceExample.zip

ETB trace

Note: The ETB does not support stream tracing.

Tested Hardware

TWR-K64F120M