− | J-Link OB is a single chip microcontroller "on-board" version of J-Link. It is designed to be a low-cost, single chip, on-board debug solution for evaluation boards. There are various J-Link-OB implementations available, which are based on different devices. This article refers to the J-Link-OB-RX621-ARM-SWD which is a J-Link-OB based on the Renesas RX621 series devices which is capable of debugging ARM based target devices like the Renesas Synergy series devices. For more information about what J-Link-OB, please refer to [https://www.segger.com/jlink-ob.html https://www.segger.com/jlink-ob.html] |
||
− | |||
− | == Enumeration under Ubuntu running in VirtualBox fails == |
||
− | |||
− | === Problem Description === |
||
− | Under special circumstances and with a special setup, it could happen with older bootloader versions of the J-Link-OB-RX621-ARM-SWD, that enumerating via USB in a Ubuntu environment running in VirtualBox failed and J-Link was not detected properly under Ubuntu. SEGGER has reproduced the issue with the following setup but it may also occur under other constellations as well: |
||
− | * Host OS: Win7 64-bit |
||
− | * VirtualBox: Version 5.0.18 |
||
− | * VirtualBox guest OS: Ubuntu 14.04 LTS |
||
− | |||
− | The problem only occurred if the J-Link was enumerating directly inside the VirtualBox guest OS. If it initially enumerated under the host OS and was connected to the VirtualBox guest OS later on, it worked fine. |
||
− | |||
− | === Affected Evaluation Boards === |
||
− | This J-Link-OB model for example is used on the Renesas Synergy development kits. |
||
− | |||
− | === Replacing the Bootloader (Fix) === |
||
− | As the fix requires to replace the bootloader of the J-Link OB, which can result (even if very unlikely) in a unusable J-Link-OB, the fix for this is not automatically applied when a new version of the J-Link software is installed. In the following it is described how to replace the bootloader of the J-Link-OB. |
||
− | |||
− | '''The following should only be done if you are affected by this problem. Please make sure that power supply to the J-Link-OB is stable. Unstable power supply during bootloader replacement can result in an unusable J-Link-OB.''' |
||
− | |||
− | Download and install the latest J-Link software: |
||
− | * [https://www.segger.com/jlink-software.html Download] |
||
− | Start J-Link Commander and perform firmware update if asked for |
||
− | |||
− | Execute '''updatebtl''' command |
||
− | SEGGER J-Link Commander V5.41b (Compiled May 3 2016 13:50:50) |
||
− | DLL version V5.41b, compiled May 3 2016 13:50:27 |
||
− | |||
− | Connecting to J-Link via USB...O.K. |
||
− | Firmware: J-Link OB RX621-ARM-SWD V1 compiled May 3 2016 12:18:23 |
||
− | Hardware version: V2.10 |
||
− | S/N: 708000000 |
||
− | VTref = 3.300V |
||
− | |||
− | |||
− | Type "connect" to establish a target connection, '?' for help |
||
− | J-Link>updatebtl |
||
− | O.K. |
||
− | J-Link> |