− | + | The device uses custom reset which performs a reset via the SACI interface: |
|
+ | *In case of a valid application is programmed, the MCU will be halted on the reset vector (application entry point). |
||
+ | *In case of no valid application is programmed, the MCU will be halted in a so called debug loop |
||
+ | |||
===Attach=== |
===Attach=== |
||
Revision as of 09:38, 17 May 2023
The TI CC2340 devices are Cortex-M0 based wireless MCUs.
Contents
Flash Banks
Internal Flash
Flash Bank | Base address | Size | J-Link Support |
---|---|---|---|
Program Flash | 0x00000000 | 512 KB | |
CCFG Flash | 0x4E020000 | 2 KB |
CCFG Flash
- Describe CCFG Flash restriction here.
!!!TBD!!!
Device Specific Handling
Reset
The device uses custom reset which performs a reset via the SACI interface:
- In case of a valid application is programmed, the MCU will be halted on the reset vector (application entry point).
- In case of no valid application is programmed, the MCU will be halted in a so called debug loop
Attach
Limitations
Flasher Stand-Alone Mode
Not supported yet. Support will be implemented soon.
Attach
Attach is not supported because a device specific initialization sequence is required.
Evaluation Boards
- TI LP-EM-CC2340R5 evaluation board: http://wiki.segger.com/TI_LP-EM-CC2340R5
Example Application