The TI CC2340 devices are Cortex-M0 based wireless MCUs.

Flash Banks

Internal Flash

Flash Bank Base address Size J-Link Support
Program Flash 0x00000000 512 KB YES.png
CCFG Flash 0x4E020000 2 KB YES.png

CCFG Flash

  • Describe CCFG Flash restriction here.

!!!TBD!!!


Device Specific Handling

Connect

A device specific connect sequence is executed which supports:

  • Connecting to a device with invalid CCFG block. In this case, a default CCFG will be programmed as part of the connect.
  • Connecting to a device with valid CCFG block

Reset

The device uses custom reset which performs a reset via the SACI interface:

  • In case of a valid application is programmed, the MCU will be halted on the reset vector (application entry point).
  • In case of no valid application is programmed, the MCU will be halted in a so called debug loop

Limitations

Flasher Stand-Alone Mode

Not supported yet. Support will be implemented soon.

Attach

Attach is not supported because a device specific initialization sequence is required.

Security

Connecting to a protected device is not supported yet.

Evaluation Boards

Example Application