Difference between revisions of "Tracing on NXP Kinetis MK60N512"

From SEGGER Wiki
Jump to: navigation, search
(Streaming trace)
Line 4: Line 4:
 
The NXP Kinetis MK60N512 MCU implements tracing via pins or via on-chip trace buffer (ETB), so a J-Trace as well as the ETB can be used for tracing.
 
The NXP Kinetis MK60N512 MCU implements tracing via pins or via on-chip trace buffer (ETB), so a J-Trace as well as the ETB can be used for tracing.
   
= Minimum requirements =
+
== Minimum requirements ==
 
In order to use trace on the NXP Kinetis MK60N512 MCU devices, the following minimum requirements have to be met:
 
In order to use trace on the NXP Kinetis MK60N512 MCU devices, the following minimum requirements have to be met:
 
* J-Link software version V6.18c or later
 
* J-Link software version V6.18c or later
Line 10: Line 10:
 
* J-Trace PRO for Cortex-M HW version V1.0 or later
 
* J-Trace PRO for Cortex-M HW version V1.0 or later
   
= Sample project =
+
== Sample project ==
== Streaming trace ==
+
=== Streaming trace ===
 
The following sample project is designed to be used with J-Trace PRO and Ozone to demonstrate streaming trace. The project has been tested with the minimum requirements mentioned above and a TWR-K60N512(SCH-26548 Rev.A) Towerboard. The sample project comes with a pre-configured project file for Ozone that runs out-of-the box. In order to rebuild the sample project, [https://www.segger.com/embedded-studio.html SEGGER Embedded Studio] can be used.
 
The following sample project is designed to be used with J-Trace PRO and Ozone to demonstrate streaming trace. The project has been tested with the minimum requirements mentioned above and a TWR-K60N512(SCH-26548 Rev.A) Towerboard. The sample project comes with a pre-configured project file for Ozone that runs out-of-the box. In order to rebuild the sample project, [https://www.segger.com/embedded-studio.html SEGGER Embedded Studio] can be used.
   
Line 20: Line 20:
 
To create your own .JLinkScriptfile you can use the following project as reference: [https://wiki.segger.com/Tracing_on_ST_STM32F407_(SEGGER_Cortex-M_Trace_Reference_Board) Tracing on SEGGER_Cortex-M_Trace_Reference_Board]
 
To create your own .JLinkScriptfile you can use the following project as reference: [https://wiki.segger.com/Tracing_on_ST_STM32F407_(SEGGER_Cortex-M_Trace_Reference_Board) Tracing on SEGGER_Cortex-M_Trace_Reference_Board]
   
== ETB trace ==
+
=== ETB trace ===
 
'''Note:''' The ETB does not support stream tracing.
 
'''Note:''' The ETB does not support stream tracing.
   
= Tested Hardware =
+
== Tested Hardware ==
 
[[File:TWR-K60N512.jpg|left|thumb|TWR-K60N512(SCH-26548 Rev.A)]]
 
[[File:TWR-K60N512.jpg|left|thumb|TWR-K60N512(SCH-26548 Rev.A)]]

Revision as of 18:02, 13 November 2020

This article describes how to get started with trace on the NXP Kinetis MK60N512 MCU. This article assumes that there is already a basic knowledge about trace in general (what is trace, what different implementations of trace are there, etc.). If this is not the case, we recommend to read Trace chapter in the J-Link User Manual (UM08001). The NXP Kinetis MK60N512 MCU implements tracing via pins or via on-chip trace buffer (ETB), so a J-Trace as well as the ETB can be used for tracing.

Minimum requirements

In order to use trace on the NXP Kinetis MK60N512 MCU devices, the following minimum requirements have to be met:

  • J-Link software version V6.18c or later
  • Ozone V2.46a or later (if streaming trace and / or the sample project from below shall be used)
  • J-Trace PRO for Cortex-M HW version V1.0 or later

Sample project

Streaming trace

The following sample project is designed to be used with J-Trace PRO and Ozone to demonstrate streaming trace. The project has been tested with the minimum requirements mentioned above and a TWR-K60N512(SCH-26548 Rev.A) Towerboard. The sample project comes with a pre-configured project file for Ozone that runs out-of-the box. In order to rebuild the sample project, SEGGER Embedded Studio can be used.

NXP_Kinetis_MK60N512_25_MHz_TraceExample.zip

Note: The example is shipped with a compiled .JLinkScriptfile, should you need the original source, please get in touch with SEGGER directly via our support system: https://www.segger.com/ticket/.

To create your own .JLinkScriptfile you can use the following project as reference: Tracing on SEGGER_Cortex-M_Trace_Reference_Board

ETB trace

Note: The ETB does not support stream tracing.

Tested Hardware

TWR-K60N512(SCH-26548 Rev.A)