On early batches of the nRF51822 series, the reset functionality was not correctly disabled when entering '''debug interface mode'''.
 
On early batches of the nRF51822 series, the reset functionality was not correctly disabled when entering '''debug interface mode'''.
 
===huhu===
 
===huhu===
  +
blablabla
 
   
 
==Using J-Link SWD Isolator==
 
==Using J-Link SWD Isolator==
Line 21: Line 21:
 
zz = week of production
 
zz = week of production
 
Only devices produced at yy = 12, zz = 30 or later can be used with the J-Link SWD Isolator. Some very early devices do not even have N1822 or any date code on them. These are also affected by the pin reset problem.
 
Only devices produced at yy = 12, zz = 30 or later can be used with the J-Link SWD Isolator. Some very early devices do not even have N1822 or any date code on them. These are also affected by the pin reset problem.
  +
  +
===hehe===
  +
blablabla

Revision as of 21:07, 17 March 2017

blabla

SWDIO behavior on early batches

The SWDIO line on the nRF51822 series can be configured to also function as a reset pin if the SWDIO line is pulled LOW for more than 100us. After power on, the device is in normal mode where the reset functionality of the pin is enabled. As soon as activity on the SWCLK line is recognized, the device will enter debug interface mode where the reset functionality of SWDIO is disabled. For further information about the different modes, please refer to the reference manual of the device. On early batches of the nRF51822 series, the reset functionality was not correctly disabled when entering debug interface mode.

huhu

blablabla

Using J-Link SWD Isolator

Read SWDIO behavior on early batches first.

As the J-Link SWD Isolator can only keep the last level of the SWDIO pin that was driven by one side, SWDIO may stay 0 between SWD sequences. This makes it impossible to use the J-Link SWD Isolator with these early batches of the device. Unfortunately, it is also not possible to disable the pin reset functionality manually on these early devices.

To check if a specific device is affected, the device printing needs to be checked. It is of the following format:

N51822
xxxxxx
yyzzxx
x = do not care
y = Year or production
zz = week of production

Only devices produced at yy = 12, zz = 30 or later can be used with the J-Link SWD Isolator. Some very early devices do not even have N1822 or any date code on them. These are also affected by the pin reset problem.