Search results

Jump to: navigation, search

Page title matches

  • * Connect J-Link via USB to the PC ...], additional steps are required in order to enable the J-Link software to connect to J-Links via USB. These steps are described in the '''README.txt''' that
    8 KB (1,261 words) - 18:34, 2 November 2023
  • #REDIRECT [[J-Link cannot connect to the CPU]]
    46 bytes (7 words) - 09:27, 1 June 2017
  • ...ote-server/ J-Link Remote Server] makes it possible for Embedded Studio to connect to a J-Link remotely, without needing a physical connection to the J-Link. In order to connect to a J-Link Remote Server using Embedded Studio, follow these instructions:
    1 KB (153 words) - 18:30, 31 May 2019
  • ...ntentionally. Our recommendation when using the 19-pin header is to either connect that signal to pin 1 (VTref) of the J-Link/J-Trace or pull it high on the t
    433 bytes (78 words) - 14:05, 8 May 2020

Page text matches

  • ...ation and debugging of embedded systems while they are running. The probes connect the embbedded system with the computer used for development. This section i
    13 KB (1,841 words) - 10:31, 7 May 2024
  • *Connect the J-Link to JTAG connector (J17)
    887 bytes (141 words) - 15:09, 8 May 2024
  • During connect the M4 is set to execute an endless loop at 0x1FFE0000 (TCM RAM). ===Connect===
    1 KB (212 words) - 10:21, 8 April 2024
  • ===Connect===
    2 KB (279 words) - 09:41, 8 April 2024
  • *Connect the J-Link to this pins:
    1 KB (167 words) - 15:09, 8 May 2024
  • ...commend to connect the this pin as for STM32 devices this pin allows us to connect under reset. So ..., which for example remaps the debug pins, is running on the target we can connect to it.
    880 bytes (143 words) - 11:31, 13 August 2015
  • The TMS570Lx series features a so called ICEPick which requires a special connect sequence. This sequence is executed by default by the J-Link DLL if the pro == RAM initialization on connect ==
    4 KB (743 words) - 16:05, 4 August 2023
  • | [[#USB | USB]] || USB || Connect to J-Link via USB | [[#IP | IP]] || IP || Connect to J-Link via TCP/IP or to Remote Server
    52 KB (6,653 words) - 12:04, 22 April 2024
  • * Connect J-Link via USB to the PC ...], additional steps are required in order to enable the J-Link software to connect to J-Links via USB. These steps are described in the '''README.txt''' that
    8 KB (1,261 words) - 18:34, 2 November 2023
  • ...-EVAL evaluation boards, make sure that JP4 is in position 1-2 in order to connect the MCU TDO/SWO signal to the TDO/SWO pin on the debug connector.
    206 bytes (41 words) - 12:40, 17 August 2015
  • ...ore) and RZ/G1M (Cortex-A15 dual core) processors. It provides examples to connect to the different cores as well as a J-Flash project + custom RAMCode, which
    3 KB (487 words) - 08:58, 1 July 2016
  • ...-> Properties -> Debugger -> J-Link Options -> Execute J-Link Commands on Connect''':
    4 KB (609 words) - 09:25, 27 May 2021
  • [[Connect to remote J-Link via J-Link Tunnel Server]]
    10 KB (1,458 words) - 10:45, 7 May 2024
  • '''J-Link EDBG unable to connect to target'''
    689 bytes (117 words) - 18:45, 26 April 2016
  • == How to connect an external J-Link == ...econfigured via utilities from Silicon Labs, to allow an external probe to connect.
    1 KB (170 words) - 18:35, 19 May 2016
  • ...no generic way how to implement flash programming because the used pins to connect the SPI flash is not defined. Different pins can be used for the same OCTAS
    5 KB (834 words) - 15:10, 8 May 2024
  • * Connect the debug interface signals manually (e.g. using jumping wires) as describe
    943 bytes (132 words) - 10:40, 23 May 2016
  • J-Link will connect to the MCU using the regular target interface (usually, JTAG or SWD). == Complications with direct connection (Connect) ==
    12 KB (1,976 words) - 16:38, 10 October 2023
  • It is mandatory to connect the reset pin of the Kinetis devices to J-Link. Otherwise, proper functiona
    4 KB (675 words) - 13:37, 9 December 2022
  • In order to connect to the CPU's debug port, at first the board needs to be manually reconfigur
    291 bytes (50 words) - 08:57, 1 July 2016
  • ..._SetIndexAHBAPToUse]] || Selects a specific AHB-AP to be used to connect to a Cortex-M device. ..._SetIndexAPBAPToUse]] || Selects a specific APB-AP to be used to connect to a Cortex-A or Cortex-R device.
    77 KB (9,842 words) - 11:00, 11 April 2024
  • #Open the J-Link Commander. It should connect to a J-Link automatically, if one is present.
    3 KB (446 words) - 14:36, 8 February 2024
  • * Connect J-Link via USB to the PC
    1 KB (180 words) - 11:04, 20 March 2017
  • J-Link script files are necessary to connect to the different A9 cores of the device. As a first step, it is mandatory to connect to the first A9 core (Core 0) and enable any other A9 core (Core 1-3) which
    3 KB (458 words) - 15:53, 15 August 2023
  • J-Link script files are necessary to connect to both A7 cores and the M4 core of the iMX7D MCU. ##Connect the DEBUG UART via USB to the PC
    4 KB (740 words) - 10:14, 17 January 2024
  • ...no generic way how to implement flash programming because the pins used to connect the SPI flash are not defined. Different pins can be used for the same QUAD
    7 KB (1,150 words) - 15:10, 8 May 2024
  • ===Connect===
    3 KB (462 words) - 09:39, 15 April 2024
  • == Device specific connect == ...he best debugging experience for the most common setups, a device specific connect is implemented for the STM32 devices.
    13 KB (2,031 words) - 17:27, 2 April 2024
  • *Manually connect Pin1 of the SWD debug connector (P1) to 3.3V (VTref) *Connect the J-Link to the target using the SWD debug connector (P1)
    282 bytes (50 words) - 19:06, 10 February 2017
  • ...to attach to a running target. J-Link needs to perform a reset during the connect phase, to guarantee a stable debug connection and session. This behavior wa The XMC 4xxx-series requires a specific connect sequence in which the JTAG chain is configured. By default, the XMC4xxx dev
    4 KB (637 words) - 11:58, 17 November 2023
  • #Connect the Flasher Portable via USB to the PC #Connect the Flasher to the PC via USB (PROG button *not* pressed)
    2 KB (273 words) - 10:50, 18 November 2021
  • Before J-Link can connect to core 1, please make sure that the application running on core 0 has alre ...connect to core 0 when selecting "'''Cyclone V'''" as device. In order to connect to core 1, just specify the J-Link script file from below to be used for th
    2 KB (282 words) - 18:43, 2 March 2020
  • The RMxxL series features a so called ICEPick which requires a special connect sequence. This sequence is executed by default by the J-Link DLL if the pro == RAM initialization on connect ==
    2 KB (356 words) - 15:17, 18 October 2021
  • ...debugger which drives the debug signals by default. In order to be able to connect with a J-Link to the CC2640R2 device, the jumper as shown on image below ne
    291 bytes (55 words) - 17:35, 22 March 2018
  • # connect to the J-Link gdb server
    4 KB (530 words) - 14:22, 10 May 2024
  • * JP1: Connect PE4 to trace connector CN13 as TRACE_D1 by setting JP1 on position 1-2 * JP2: Connect PE3 to trace connector CN13 as TRACE_D0 by setting JP2 to position 1-2
    324 bytes (60 words) - 09:16, 31 May 2017
  • #REDIRECT [[J-Link cannot connect to the CPU]]
    46 bytes (7 words) - 09:27, 1 June 2017
  • *Connect the J-Link to the 20 pin JTAG connector (J6)
    902 bytes (138 words) - 15:11, 8 May 2024
  • *Connect the J-Link to the JTAG header (JP1)
    909 bytes (134 words) - 15:12, 8 May 2024
  • # Initial interface speed before/during connect #:* The interface speed before connect can be specified in the field '''Initial speed''' marked below
    9 KB (1,396 words) - 15:27, 18 October 2021
  • ...o, by default the following dialog pops up, allowing to select a J-Link to connect to: A J-Link is identified by its serial number (S/N), so in order to connect to a specific J-Link, the S/N needs to be specified, to avoid the selection
    919 bytes (153 words) - 09:36, 24 July 2017
  • # Connect your JLink debug probe with e.g. jumper wires with header J1 like described | Pin 3 || Do not connect, leave open
    2 KB (290 words) - 14:32, 10 May 2024
  • ...J-Link Remote Server] makes it possible for IAR Embedded Workbench IDE to connect to a J-Link remotely, without needing a physical connection to the J-Link.
    10 KB (1,678 words) - 15:29, 18 October 2021
  • Mainly used to set some global DLL variables to customize the normal connect procedure. ...ot in a script file or empty (simply returns 0), this has no effect on the connect sequence of J-Link.
    109 KB (15,505 words) - 08:38, 25 April 2024
  • ...4-bit writes. The following memory ranges are initialized by the J-Link on connect by default. Other ranges needs to be initialized by the application / boot ...is not possible to run a debug session in parallel with SystemView, as the connect from SystemView will reinitialize the ECC RAM init and overwrite the RTT bu
    2 KB (325 words) - 15:19, 29 November 2023
  • * normal connect procedure. For ARM CoreSight devices this may be specifying the
    2 KB (309 words) - 12:36, 24 January 2018
  • *Connect the J-Link to Target In (9-Pin Cortex-M connector; marked as number 2 in th
    1 KB (163 words) - 15:12, 8 May 2024
  • *Connect the J-Link via P11 to the target board
    971 bytes (138 words) - 15:12, 8 May 2024
  • *On connect 32 KB at 0x20000000 will be initialized. ===Connect===
    2 KB (219 words) - 11:19, 10 October 2023
  • ==How to connect a J-Link to the Adafruit Bluefruit LE UART Friend== # Connect a external power supply to the GND pin for ground and 5 V to the VIN pin.
    1 KB (164 words) - 14:31, 10 May 2024
  • == How to connect an external J-Link to the Eval-M1-1302 board == * Connect your J-Link with jumper wires to the connector ''X204 debug'' marked red on
    1 KB (177 words) - 10:00, 24 July 2019
  • The TWR-KV58F220M eval board supports to connect an external J-Link for debugging. However, by default the board is shipped
    479 bytes (78 words) - 12:23, 22 February 2018
  • ...o actually integrate the resulting SFL binary into the J-Link software and connect it with support for your new device, please refer to the [[J-Link_Device_Su
    24 KB (3,557 words) - 14:59, 20 November 2023
  • == Device specific connect == On connect, the device security is checked. If security is set (and recoverable) the u
    6 KB (932 words) - 09:10, 7 February 2024
  • Eliminate the first level USB 3.0 hub and connect the other hubs directly to the PC:
    2 KB (241 words) - 11:02, 14 May 2018
  • = How to connect with J-Link = ...(XDS110) which drives the debug signals by default. In order to be able to connect with a J-Link to the CC3220SF device, the jumpers as shown on image below n
    2 KB (317 words) - 14:32, 10 May 2024
  • # Connect the J-Trace via the trace connector to your target.
    5 KB (873 words) - 11:49, 22 April 2024
  • To connect J-Link to the CC1350 LaunchPad some of jumpers need to be removed.
    248 bytes (41 words) - 14:32, 10 May 2024
  • # Connect your debug probe through USB or Ethernet to your PC. ...icking your debug probe again. The new value should show up. Alternatively connect to your target device that supports SWO with J-Link Commander and execute c
    2 KB (385 words) - 16:19, 20 April 2018
  • The connect sequence of PSoC 4 devices is very time critical and is thus performed from
    6 KB (741 words) - 18:25, 30 November 2023
  • ...no generic way how to implement flash programming because the pins used to connect the SPI flash are not defined. ...default. Please refer to the ST board manual for information about how to connect the pins.
    20 KB (3,262 words) - 15:02, 8 May 2024
  • *Connect the J-Link to the 20-pin JTAG debug connector (CN9)
    2 KB (303 words) - 15:13, 8 May 2024
  • ...unlock process will then be handled automatically by J-Link when trying to connect to the device.
    971 bytes (143 words) - 14:23, 10 May 2024
  • * Connect J-Link via USB to the PC
    1 KB (189 words) - 09:48, 18 May 2018
  • Quote from Nordic Semiconductor: ''"Connect debugger (with trace functionality) to target device, making sure trace pin
    4 KB (689 words) - 15:38, 15 August 2023
  • = How to connect J-Link =
    959 bytes (132 words) - 17:38, 4 July 2018
  • In order to connect to the LAUNCHXL CC2650 board via J-Link the following jumpers must be '''op
    391 bytes (63 words) - 18:14, 3 July 2018
  • On each connect the J-LINK checks for a read protection and offers to "Unsecure Chip"
    887 bytes (143 words) - 12:26, 5 July 2018
  • == My application crashes when I connect SystemView. What might be wrong? ==
    7 KB (1,172 words) - 12:09, 24 April 2024
  • ...device selection is mandatory to make sure that J-Link applies the correct connect and reset sequences to the Zynq 7000 series devices. By selecting "generic The ZedBoard provides a Xilinx specific 14-pin debug connector. In order to connect J-Link to this board, the [https://www.segger.com/products/debug-probes/j-l
    1 KB (203 words) - 11:46, 1 October 2018
  • ...device selection is mandatory to make sure that J-Link applies the correct connect and reset sequences to the Zynq 7000 series devices. By selecting "generic The MicroZed provides a Xilinx specific 14-pin debug connector. In order to connect J-Link to this board, the [https://www.segger.com/products/debug-probes/j-l
    2 KB (320 words) - 18:31, 1 October 2018
  • ...ot be guaranteed. This is mainly because the TLE987x series need a special connect sequence that makes sure that TCK/SWCLK and TMS/SWDIO are sampled with the It is mandatory to connect the reset pin of the device to the J-Link debug connector. J-Link needs to
    2 KB (319 words) - 15:06, 9 February 2021
  • ...ebug connection to the device, J-Link disables the watchdog as part of the connect sequence.
    989 bytes (130 words) - 16:44, 24 October 2018
  • ...ase of the J-Link EDU Mini that pin is used as nTRST instead to be able to connect to target devices as well that have that signal routed to their target devi
    1 KB (216 words) - 11:21, 27 June 2019
  • ...MCU. This protocol specifies the following pins which are all mandatory to connect: On the BM8x EVB connector J301 is used to connect J-Link to the IS2083 MCU.
    4 KB (580 words) - 11:04, 6 August 2019
  • | -SelectEmuBySN || Specifies to connect to a J-Link with a specific S/N. Only valid for LAN mode. | -TunnelServer || Specify a tunnel server to connect to (default: jlink.segger.com:19020). Only valid for tunnel mode.
    7 KB (984 words) - 16:27, 31 August 2023
  • The J-Link DLL offers a unlock of the device on the next connect after erase. ...s provide ECC protected internal RAM. By default, J-Link resets the MCU on connect and initializes the RAM contents to 0x00. This is done for the following re
    6 KB (926 words) - 09:40, 28 February 2024
  • In order to connect to and debug one of the available Cortex-R5 on the UltraScale+ series, an U == Connect ==
    2 KB (252 words) - 19:05, 25 March 2019
  • * Connect the J-Link-OB to your PC Type "connect" to establish a target connection, '?' for help
    8 KB (1,201 words) - 10:22, 26 March 2019
  • *Start RTT Viewer and connect with the following settings:
    2 KB (273 words) - 10:48, 28 January 2021
  • ...are offers a convenient method to initialize the work RAM of the device on connect to allow initial read access. ...Command("SetInitWorkRAMOnConnect = 1"); // Work RAM will be initialized on connect
    2 KB (326 words) - 11:01, 10 July 2023
  • * [[J-Link cannot connect to the CPU]] * [[How to connect JTAG nTRST when using 19-pin trace header]]
    16 KB (1,908 words) - 10:22, 8 May 2024
  • WebUSB provides a way for websites to connect to users' USB devices. A web browser that implements WebUSB enables a web a
    2 KB (295 words) - 15:20, 25 June 2019
  • * Connect to your device
    495 bytes (73 words) - 15:30, 31 May 2019
  • If you need to connect a client to a web-based service, for instance a service with a REST API, th If you are setting up a server that you wish to connect to using a web browser such as Edge, Firefox, or Chrome, you must select on
    18 KB (2,394 words) - 09:07, 27 May 2021
  • .... To get the supported SWO speeds for your emulator, use J-Link Commander, connect to your target and execute the command "SWOSpeed" without quotations.
    3 KB (518 words) - 10:08, 10 October 2022
  • ...ote-server/ J-Link Remote Server] makes it possible for Embedded Studio to connect to a J-Link remotely, without needing a physical connection to the J-Link. In order to connect to a J-Link Remote Server using Embedded Studio, follow these instructions:
    1 KB (153 words) - 18:30, 31 May 2019
  • |Calls [[connect()]] to send a SYN to the server to establish a connection. ...ts for data processing such as a [[recv()]] timeout are independent from a connect timeout and can be much higher.
    5 KB (935 words) - 11:47, 14 June 2019
  • To be able to connect to this core it first needs to be enabled via an application running in the After the APP core is enabled you can connect to it and download the application your are looking to trace. Make sure to
    4 KB (724 words) - 10:18, 14 June 2022
  • * Modern (high-end) CPUs typically come with a Cache, as the memory they connect to cannot keep up with the high clock rate. In order to avoid wait state (C
    8 KB (1,313 words) - 00:08, 18 June 2019
  • ! WS State before connect !! FUS/WS was updated<br>after connect !! Is WS started<br>on disconnect # Connect to the device.
    12 KB (1,803 words) - 16:03, 22 September 2023
  • ...t consists of 2 CPU-TAPs (each a RISC-V with IRLen == 5) that specifies to connect to TAP #0 or #1 resprectively.
    8 KB (1,297 words) - 12:04, 16 March 2023
  • To connect to a target device via the debug interface, J-Link / Flasher needs to setup # Issue "r0" followed by "r1" command (do NOT call "connect" or anything else!)
    2 KB (262 words) - 13:41, 5 June 2020
  • || Select the debug interface to use to connect to the target device. || The name of the device to connect to.
    10 KB (1,529 words) - 11:30, 29 August 2019
  • | --usb ''SerialNo'' || Not set || Connect to J-Link with SN "SerialNo" via USB. | --ip ''sIP'' || Not set || Connect to J-Link with IP "sIP" via IP.
    3 KB (385 words) - 15:38, 29 June 2022
  • J-Link will connect to the device in this state and halt it. Thus, J-Link will connect to the device, trigger a reset via nRESET and halt the device 100ms afterwa
    6 KB (1,037 words) - 16:04, 4 August 2023
  • =Connect=
    1 KB (241 words) - 16:34, 19 April 2022
  • ...(GDB) via TCP/IP. It is required for toolchains using the GDB protocol to connect to J-Link. The J-Link DLL / J-Flash checks the write protection on connect (e.g. when triggering read-back) and offers to perform a
    92 KB (14,353 words) - 12:06, 7 March 2024
  • *Connect the J-Link to the 20-pin debug connector.
    1 KB (159 words) - 15:14, 8 May 2024
  • ...o not plan to supply power to the target via this pin it is recommended to connect it to GND. ...o not plan to supply power to the target via this pin it is recommended to connect it to GND.
    4 KB (672 words) - 11:09, 4 January 2024
  • ===Connect=== *The device uses custom connect.
    989 bytes (134 words) - 12:13, 13 June 2023
  • *Connect the J-Link to Target In
    960 bytes (152 words) - 15:14, 8 May 2024
  • ===Connect=== *The device uses custom connect.
    1,007 bytes (134 words) - 13:38, 13 June 2023
  • *Connect the J-Link to Target In
    938 bytes (144 words) - 15:14, 8 May 2024
  • * Now connect the board with e.g. jumperwires to your J-Link probe. .... How is explained in the J-Link user guide UM08001. Alternatively you can connect an external 5 V power supply as well to the target board pin and use a seco
    3 KB (406 words) - 15:14, 8 May 2024
  • * Now connect the board with e.g. jumperwires to your J-Link probe.
    2 KB (364 words) - 15:15, 8 May 2024
  • # Connect to the J-Link GDB Server. This can be achieved via these commands:
    1 KB (231 words) - 17:40, 21 November 2019
  • == Connect sequence == === Standard connect sequence ===
    5 KB (771 words) - 16:18, 9 August 2022
  • ...come with an standard debug connector but with 4 pins which can be used to connect an J-Link to the MCU. * Now connect the board with e.g. jumperwires to your J-Link probe.
    2 KB (377 words) - 15:15, 8 May 2024
  • | Target connect | Target connect
    9 KB (1,399 words) - 12:07, 24 February 2020
  • Ozone can connect to a remote J-Link/J-Trace debug probe in order to debug on a remote target Both Ozone and the J-Link Remote Server then connect to this tunnel server instead of connecting to each other directly.
    3 KB (428 words) - 15:32, 4 November 2021
  • ...ation dialog is used to set all necessary device specifics to successfully connect and read/send RTT data from/to the target device. # Select the target device to connect to. This allows J-Link to search in the known RAM of the target.
    21 KB (2,872 words) - 09:41, 4 March 2024
  • ...come with a standard debug connector but with 4 pins which can be used to connect the J-Link to the MCU. Connect the board with e.g. jumper wires to your J-Link probe. The following table
    2 KB (357 words) - 15:15, 8 May 2024
  • ...nected to the FlexSPI bus, only. The external FlexSPI controller allows to connect several different flash types like QSPI, HyperFlash and Octaflash. Furtherm
    3 KB (440 words) - 08:04, 14 July 2023
  • ...nected to the FlexSPI bus, only. The external FlexSPI controller allows to connect several different flash types like QSPI and HyperFlash. Furthermore, the ex
    2 KB (283 words) - 12:01, 18 June 2020
  • ...st PC only and $(IPJLINK) will now expand to your global macro and you can connect to your specified J-Link in your network
    2 KB (337 words) - 14:14, 3 April 2020
  • ...e left side of the MCU. Therefore, these pads have to be wired manually to connect J-Link to the evaluation board. * Connect the board with e.g. jumper wires to your J-Link probe.
    3 KB (429 words) - 15:15, 8 May 2024
  • ...no generic way how to implement flash programming because the pins used to connect the SPI flash are not defined. Different pins can be used for the same QUAD
    1 KB (199 words) - 16:02, 13 August 2020
  • // Now, connect to the server with emVNC.exe and enter the server IP.
    4 KB (395 words) - 17:05, 21 April 2020
  • // Now, connect to the server with emVNC.exe and enter the IP of your target.
    5 KB (501 words) - 17:46, 21 April 2020
  • In order to connect to a J-Link from WSL you either have to use the Ethernet / WiFi interface ( In this example we will connect to our J-Link (connected via USB to the host) from WSL using the [[J-Link_R
    2 KB (375 words) - 16:15, 14 May 2020
  • *Connect the J-Link to the SWD header (P1)
    1 KB (169 words) - 15:15, 8 May 2024
  • | Connect || Creates a connection through t If this option is checked, J-Flash will connect to J-Link / Flasher over the USB port. The default device number is 0. For
    72 KB (10,586 words) - 13:00, 25 March 2024
  • letting you select the needed configurations to connect to J-Link and the target.
    3 KB (562 words) - 16:22, 12 May 2020
  • ...ntentionally. Our recommendation when using the 19-pin header is to either connect that signal to pin 1 (VTref) of the J-Link/J-Trace or pull it high on the t
    433 bytes (78 words) - 14:05, 8 May 2020
  • | -IP || Connect to J-Link via TCP/IP. | -SelectEmuBySN || Connect to J-Link via its serial.
    2 KB (323 words) - 22:06, 1 March 2021
  • Selects IP as host interface to connect to J-Link. Connect to a J-Link with a specific serial number via USB.
    6 KB (911 words) - 15:08, 12 May 2020
  • Additionally, on connect, it unsecures a read-protected STM32 device by re-programming the option by | [[#-IP | -IP]] || Selects IP as host interface to connect to J-Link. Default host interface is USB.
    6 KB (759 words) - 13:20, 18 November 2022
  • J-Link GDB Server is a remote server for GDB making it possible for GDB to connect to and communicate with the target device via J-Link. ...figuration dialog pops up, letting you select the needed configurations to connect to J-Link and target.
    63 KB (8,889 words) - 09:59, 29 November 2023
  • to calculate the correct SWO speed or to connect to a running J-Link GDB Server. ...clock speed at startup to be able to calculate the correct SWO speed or to connect to a running J-Link GDB Server.<br>
    13 KB (1,666 words) - 15:42, 24 October 2022
  • ...nected to the FlexSPI bus, only. The external FlexSPI controller allows to connect several different flash types like QSPI, HyperFlash and Octaflash. Furtherm
    6 KB (941 words) - 16:37, 16 August 2023
  • <li> Select J-Link and press '''OK''' to connect to the target via J-Link.<br> Select '''File''' | '''Connection''' | '''Connect to Target'''.<br>
    22 KB (3,101 words) - 10:27, 16 July 2020
  • Connect the J-Link pins to corresponding cables as listed in the table below:
    2 KB (289 words) - 17:24, 18 June 2020
  • Lines which are used to connect the items of a tree. The lines connect the button bitmaps
    5 KB (826 words) - 10:51, 14 July 2020
  • | Connect || Creates a connection through the J-Link using the | USB || Connect to emulator with the specified device number (default: 0) via USB port.
    46 KB (6,804 words) - 10:32, 27 February 2023
  • *Connect the J-Link to the SWD header (J6)
    981 bytes (151 words) - 15:16, 8 May 2024
  • * Now connect the board with e.g. jumperwires to your J-Link probe. * Connect an external DC power supply to the board as follows:
    2 KB (349 words) - 15:16, 8 May 2024
  • ...// Connect the interface if necessary. ...done compile and download the application to the STM32F746G Discovery and connect an Ethernet cable. As soon as the IP connection has been established you ca
    9 KB (1,201 words) - 10:29, 21 August 2020
  • *Connect the J-Link to the JTAG header (J5)
    1 KB (159 words) - 15:16, 8 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    1 KB (158 words) - 15:36, 22 February 2024
  • ...ard debug connector. Therefore, these signals have to be wired manually to connect the J-Link to the evaluation board. The following guide will describe how t * Connect the board with jumping wires to your J-Link (see table below)<br>For inform
    2 KB (286 words) - 15:16, 8 May 2024
  • * A way to connect to the 10 pin debug connector of the Arduino Due board e.g. [https://www.se * Connect your board to a J-Link as explained above and test the connection with J-Li
    4 KB (587 words) - 14:25, 10 May 2024
  • * Connect your board to a J-Link as explained above and test the connection with J-Li
    4 KB (649 words) - 14:25, 10 May 2024
  • * Connect your board to a J-Link as explained above and test the connection with J-Li
    4 KB (662 words) - 14:26, 10 May 2024
  • * Connect your board to a J-Link as explained above and test the connection with J-Li
    4 KB (659 words) - 14:26, 10 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    1 KB (190 words) - 13:33, 23 February 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    1 KB (158 words) - 11:18, 1 March 2024
  • The GD32E507Z-EVAL does come with a JTAG connector. You only have to connect it to your J-Link and power it via the USB port (CN 100).
    1 KB (188 words) - 15:17, 8 May 2024
  • *Select and connect to Segger J-Link from the '''Targets''' window as shown below
    1 KB (185 words) - 10:03, 9 October 2020
  • Now we need to connect Cosmic IDE with Cosmic Debugger. ZAP J-Link is built to automatically find and connect to a J-Link. To start ZAP it is necessary to have one J-Link connected to t
    2 KB (304 words) - 10:27, 9 October 2020
  • ...g connector. Therefore, you can use a JTAG connector with jumper cables to connect your J-Link with the board. The following guide will describe how the GD32E * Connect the board with jumping wires to your J-Link (see table below)<br>For inform
    2 KB (285 words) - 15:17, 8 May 2024
  • ...ard debug connector. Therefore, these signals have to be wired manually to connect the J-Link to the evaluation board. The following guide will describe how t * Connect the board with jumping wires to your J-Link (see table below)<br>For inform
    2 KB (286 words) - 15:17, 8 May 2024
  • ...ition, otherwise your board might be damaged beyond recovery. Then you can connect the line by soldering a jumping wire to it. After that, connect the board with the soldered on jumping wires to your J-Link (see table belo
    2 KB (342 words) - 15:17, 8 May 2024
  • J14 SWD can be used to connect an external J-Link to the S32K144 device. A [https://www.segger.com/product
    1 KB (173 words) - 16:00, 16 November 2020
  • * Connect a J-Link or Flasher to the evaluator board using a 20-pin ribbon cable
    2 KB (358 words) - 12:46, 2 December 2020
  • *Connect the board via USB to the PC (USB is also used as power supply)
    1 KB (161 words) - 15:17, 8 May 2024
  • *Connect the J-Link to the SWD header
    1 KB (147 words) - 15:18, 8 May 2024
  • ...4-bit writes. The following memory ranges are initialized by the J-Link on connect by default. Other ranges needs to be initialized by the application / boot ...isabled after reset / by default thus needs to be enabled by the J-Link on connect. Some of them are running in permanent ''lockstep'' mode, some are operatin
    10 KB (1,543 words) - 11:09, 30 April 2024
  • *Connect the J-Link to the pins as seen in the image/table below:
    1 KB (187 words) - 15:18, 8 May 2024
  • # Connect your JLink debug probe with e.g. jumper wires with header JP4 like describe
    1 KB (151 words) - 17:33, 4 January 2021
  • *Connect the J-Link to the JTAG/TRACE header (J7)
    679 bytes (104 words) - 15:19, 8 May 2024
  • *Connect the J-Link to the JTAG/TRACE header (J7)
    679 bytes (104 words) - 15:20, 8 May 2024
  • *Connect the J-Link to the pins as seen in the image/table below:
    1 KB (171 words) - 15:20, 8 May 2024
  • ...with a standard 9-pin Cortex-M JTAG/SWD connector (U6) that can be used to connect a J-Link to the TM4C1294 MCU on the board.
    822 bytes (137 words) - 11:31, 3 February 2021
  • Connect the J-Link to the evaluation board, using jumper wires as follows:
    2 KB (305 words) - 14:48, 11 May 2022
  • # Connect Flasher Hub to power supply via USB-C # Connect Flasher Hub to LAN via Ethernet cable
    26 KB (3,744 words) - 13:56, 3 May 2024
  • # Initial interface speed before/during connect #:* The interface speed before connect can be specified in the field '''Initial speed''' marked below
    6 KB (776 words) - 14:57, 9 March 2021
  • ...g [[J-Link Script file]] can be used to automatically disable TrustZone on connect:
    9 KB (1,465 words) - 12:53, 18 March 2024
  • ...nected to the FlexSPI bus, only. The external FlexSPI controller allows to connect several different flash types like QSPI, HyperFlash and Octaflash. Furtherm
    2 KB (379 words) - 17:34, 12 January 2024
  • *Connect the J-Link to the JTAG header (JP1)
    642 bytes (98 words) - 15:20, 8 May 2024
  • (Q1) What is the expected method for IDE to connect with M0 core and M4 or M7 core? (Q2) Is it possible to connect CYT2B63BAD_M4 only from J-Link Commander without connection to CYT2B63BAD_M
    4 KB (728 words) - 11:46, 20 October 2023
  • Connect the J-Link to the evaluation board, using jumper wires as follows at connec
    2 KB (222 words) - 10:33, 20 April 2021
  • Connect the J-Link to the evaluation board, using jumper wires as follows:
    2 KB (286 words) - 16:52, 23 April 2021
  • # Connect your J-Link to your PC and to your target board.
    5 KB (813 words) - 13:57, 28 April 2021
  • * Connect the ARTY-100T board via micro USB cable to the computer * Click '''Open Target -> Auto Connect'''
    4 KB (561 words) - 15:21, 8 May 2024
  • * Connect the J-Link to the SWD header (J33 (SWD))
    1 KB (187 words) - 16:13, 1 June 2021
  • * Connect the J-Link to the SWD header (J33 (SWD))
    1 KB (187 words) - 16:13, 1 June 2021
  • * Connect the ARTY-100T board via micro USB cable to the computer * Click '''Open Target -> Auto Connect'''
    4 KB (554 words) - 15:21, 8 May 2024
  • * Connect the ARTY-100T board via micro USB cable to the computer * Click '''Open Target -> Auto Connect'''
    4 KB (554 words) - 15:21, 8 May 2024
  • * Connect the ARTY-100T board via micro USB cable to the computer * Click '''Open Target -> Auto Connect'''
    4 KB (554 words) - 15:21, 8 May 2024
  • * Connect the ARTY-100T board via micro USB cable to the computer * Click '''Open Target -> Auto Connect'''
    4 KB (554 words) - 15:21, 8 May 2024
  • * Connect the ARTY-100T board via micro USB cable to the computer * Click '''Open Target -> Auto Connect'''
    4 KB (554 words) - 15:21, 8 May 2024
  • * Connect the ARTY-100T board via micro USB cable to the computer * Click '''Open Target -> Auto Connect'''
    4 KB (554 words) - 15:21, 8 May 2024
  • * Connect the ARTY-100T board via micro USB cable to the computer * Click '''Open Target -> Auto Connect'''
    4 KB (554 words) - 15:22, 8 May 2024
  • *Connect the J-Link to the SWD header (CN2) on the SMARC module
    1 KB (174 words) - 15:22, 8 May 2024
  • *Connect the K32W041AM extension board to the OM15076-3/JN5189 carrier board *Connect the J-Link to the 10-pin SWD debug connector
    1 KB (221 words) - 15:22, 8 May 2024
  • #Connect to the target using J-Link Commander
    4 KB (594 words) - 08:59, 9 July 2021
  • * normal connect procedure. For ARM CoreSight devices this may be specifying the
    2 KB (325 words) - 18:02, 7 July 2021
  • {{Note|1=To be able to connect to the APP core it first needs to be enabled via an application running in
    2 KB (360 words) - 16:11, 2 March 2023
  • ...core lockup. The following memory ranges are initialized by the J-Link on connect by default. Other ranges needs to be initialized by the application / boot
    2 KB (267 words) - 10:23, 5 December 2023
  • *Connect the J-Link to the JTAG header (JP1)
    910 bytes (135 words) - 17:35, 14 May 2024
  • *Connect the J-Link to this pins:
    1 KB (161 words) - 17:23, 14 May 2024
  • *Connect the J-Link to the SWD header (J9)
    1 KB (205 words) - 15:23, 8 May 2024
  • ...and optionally enter the serial number or the IP address of the J-Link to connect to a specific J-Link.
    18 KB (2,855 words) - 10:02, 6 February 2024
  • *Connect the J-Link to the JTAG header (JP1)
    890 bytes (135 words) - 16:34, 14 May 2024
  • ...ence has been implemented as part of the init steps which are executed on "Connect".
    1 KB (184 words) - 10:38, 6 January 2023
  • Please note that without the STM8 adapter you have to connect the SWIM line to TCK and via a 1k resistor to PIN17.
    773 bytes (120 words) - 12:51, 14 October 2021
  • *Connect the BRD4210A extension board to the PCB4001 carrier board *Connect the J-Link to the 20-pin debug connector
    1 KB (205 words) - 15:23, 8 May 2024
  • *Connect the J-Link to the 20-pin JTAG debug connector (CN14)
    911 bytes (149 words) - 15:24, 8 May 2024
  • This article explains different methods that can be used to connect to a J-Link and debug via WiFi. ...WiFi-Bridge.png | thumb | right | 600px | Schematic drawing showing how to connect to a J-Link PRO via WiFi]]
    2 KB (318 words) - 10:03, 2 May 2024
  • ===Connect=== ...In order to establish a connection, the J-Link performs a device specific connect sequence. After executing the sequence, the Cortex-M33 is executing a test
    788 bytes (119 words) - 16:47, 4 November 2021
  • #Connect the product to be registered to your PC
    1,000 bytes (156 words) - 12:40, 22 March 2022
  • The user can connect to the J-Link OB (e.g. with [[J-Link Commander]]) and disconnect this sessi
    1 KB (221 words) - 17:03, 30 November 2021
  • ...second until the actual application boots. This would be enough time to re-connect + issue a halt request on MCUs where the reset does clear the debug logic.
    4 KB (637 words) - 18:30, 6 December 2021
  • *Connect the J-Link to the 20-pin SWD debug connector
    854 bytes (127 words) - 15:24, 8 May 2024
  • # Connect the J-Link to a machine that is running an operating system '''other than'' # Connect the unit via USB to the Windows ARM64 machine
    2 KB (322 words) - 16:38, 18 March 2022
  • *Connect the J-Link to the SWD header (J16)
    1 KB (187 words) - 15:24, 8 May 2024
  • *Connect the J-Link : VTref=J1-2 / GND=J1-10 / SWDIO=J1-4 / SWDCLK=J1-6
    1 KB (153 words) - 15:24, 8 May 2024
  • ...lt. Please refer to the Infineon board manual for information about how to connect the pins.
    4 KB (660 words) - 14:50, 13 April 2023
  • *Connect the J-Link to the debug connector (J365)
    1 KB (195 words) - 15:24, 8 May 2024
  • *Connect the J-Link debug connector.
    1 KB (157 words) - 15:25, 8 May 2024
  • *Connect the J-Link to the SWD header (CN1) on the right side with jumper cables.
    1,002 bytes (164 words) - 15:25, 8 May 2024
  • *Connect the J-Link to the SWD header (CN1) on the right side with jumper cables.
    1,002 bytes (164 words) - 15:25, 8 May 2024
  • ...only have these two devices in a network, with nothing else. I.e. directly connect the computer to the signature server, with no other network devices connect
    20 KB (3,305 words) - 17:56, 21 January 2022
  • *Connect the J-Link debug connector.
    1 KB (151 words) - 15:25, 8 May 2024
  • ===Connect=== *The J-Link determines the security state as part of the connect sequence. If a secured device is detected, an un-secure is offered via dial
    1 KB (175 words) - 14:50, 29 November 2023
  • This guide also assumes that you know how to connect the board to J-Link and how to power both.
    4 KB (710 words) - 11:24, 23 October 2023
  • J-Link supports debugging for the Cortex-M4. During connect the M4 is set to execute an endless loop at 0x1FFE0000 (TCML RAM) and after
    346 bytes (53 words) - 17:15, 4 February 2022
  • J-Link supports debugging for the Cortex-M4. During connect the M4 is set to execute an endless loop at 0x1FFE0000 (TCML RAM) and after
    669 bytes (104 words) - 12:42, 16 February 2022
  • *Connect the J-Link to the "JLINK" 20 pin header
    1 KB (165 words) - 15:25, 8 May 2024
  • # Connect TDO (T7), TDI (T8), TCK (T9), TMS (T10), and TRST (T11) to external debug p After that, connect the board with the soldered on wires to your J-Link (see table below)<br>Fo
    1 KB (219 words) - 15:25, 8 May 2024
  • * [[How_to_connect_JTAG_nTRST_when_using_19-pin_trace_header | Connect nTRST using 19-pin trace header]] ...ect_connection_without_DHCP_to_the_host_PC.27s_Ethernet_interface | How to connect the J-Trace Pro directly via Ethernet to host PC without a router or switch
    6 KB (895 words) - 14:05, 5 June 2023
  • *For board REV D remove jumper J20 3-4 and connect pin 4 of J20 to any ground e.g. TP4. Keep J25 open. *Connect the J-Link to the debug connector (J21)
    1 KB (188 words) - 15:26, 8 May 2024
  • *Connect the J-Link to the debug connector (J3)
    1 KB (153 words) - 15:26, 8 May 2024
  • *Connect the J-Link to the debug header (J13 or J20)
    2 KB (296 words) - 15:26, 8 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    1 KB (158 words) - 18:02, 27 February 2024
  • *Connect the J-Link to the pins as seen in the image below:
    1 KB (158 words) - 15:26, 8 May 2024
  • ...et(). Mainly used to set some global DLL variables to customize the normal connect procedure.
    12 KB (1,461 words) - 17:32, 6 May 2024
  • *Connect the J-Link to the JTAG header (J5)
    1 KB (162 words) - 15:26, 8 May 2024
  • *Connect the J-Link to the JTAG header (J5)
    1 KB (168 words) - 15:30, 8 May 2024
  • *Connect the J-Link to the JTAG header (J5)
    1 KB (162 words) - 15:30, 8 May 2024
  • *Connect the J-Link to the SWD pins (P3)
    1 KB (168 words) - 15:32, 8 May 2024
  • *Connect the J-Link to the JTAG header (J5)
    1 KB (162 words) - 15:32, 8 May 2024
  • *Connect the J-Link to the JTAG header (J5)
    1 KB (162 words) - 15:32, 8 May 2024
  • *Connect the J-Link to the JTAG header (J5)
    1 KB (162 words) - 15:32, 8 May 2024
  • *Connect the J-Link to the SWD header (CN2)
    817 bytes (132 words) - 15:33, 8 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    1 KB (140 words) - 15:35, 22 February 2024
  • *Connect the J-Link to the debug header (J13 or J20)
    2 KB (299 words) - 15:33, 8 May 2024
  • Notes : For compatibility with interfaces that need to connect in any way this sample calls connect and disconnect routines
    15 KB (1,892 words) - 08:51, 22 August 2022
  • *Connect the J-Link to the pins as seen in the image/table below:
    1 KB (184 words) - 10:21, 30 August 2022
  • ...ard debug connector. Therefore, these signals have to be wired manually to connect the J-Link to the evaluation board. The following guide will describe how t * Connect the board with jumping wires to your J-Link (see table below)<br>For inform
    2 KB (256 words) - 15:33, 8 May 2024
  • ...ard debug connector. Therefore, these signals have to be wired manually to connect the J-Link to the evaluation board. The following guide will describe how t * Connect the board with jumping wires to your J-Link (see table below)<br>For inform
    2 KB (258 words) - 15:33, 8 May 2024
  • ...ly requires a flashloader and in some cases also a script defining special connect and reset sequences, required by the device.<br> In case the device requires a special connect / reset / ... sequence, a [[J-Link_script_files | J-Link script file]] need
    19 KB (2,856 words) - 08:17, 23 April 2024
  • Either the built-in [[J-Link OB]] or an external J-Link may be used to connect to the target device. * Connect J-Link to the JTAG/SWD header (J3)
    1 KB (232 words) - 15:33, 8 May 2024
  • * Connect the J-Trace Pro via Ethernet cable to a local area network. * Connect to the J-Trace Pro via [[J-Link_Commander | J-Link Commander]] to find out
    8 KB (1,367 words) - 11:16, 23 September 2022
  • *Connect the J-Link to the SWD/JTAG connector (J13)
    1 KB (166 words) - 15:33, 8 May 2024
  • To connect to the J-Link adapter, you can use USB, USB with serial number, or TCP/IP ( The option "Mode" determines how netX Studio CDT will connect to the target device:
    4 KB (655 words) - 11:44, 18 April 2024
  • ===Connect=== * On Connect, protection level is checked. For further information regarding this, pleas
    1 KB (190 words) - 16:27, 16 February 2024
  • *Connect the J-Link to the SWD header (P15)
    1,018 bytes (150 words) - 15:34, 8 May 2024
  • * Connect the hardware to J-Link using a 20pin ribbon cable for J21
    2 KB (241 words) - 15:34, 8 May 2024
  • *Connect the J-Link to the JTAG header (JP2) [[File:GD_GD32A503_EVAL_GD32A503VD Connect.png|400px]]
    981 bytes (150 words) - 15:34, 8 May 2024
  • *Connect the J-Link to the SWD header (J1)
    1,019 bytes (155 words) - 15:34, 8 May 2024
  • ===Connect===
    3 KB (446 words) - 09:40, 15 April 2024
  • * Connect the J-Link to the SWD header (J103)
    1 KB (188 words) - 15:35, 8 May 2024
  • * Connect the J-Link to the SWD header (J103)
    1 KB (170 words) - 15:35, 8 May 2024
  • *Connect the J-Link to the debug connector (J21)
    1 KB (166 words) - 15:35, 8 May 2024
  • *Connect the J-Link: VTref= CN9-32(64 on PCB) / GND=CN9-31(63 on PCB) / SWDIO=CN9-1
    1 KB (161 words) - 15:35, 8 May 2024
  • *Connect the J-Link : VTref= CN6-9 / GND=CN6-7 / SWDIO=CN9-8(18 on PCB) / SWDCLK=CN6
    999 bytes (155 words) - 15:35, 8 May 2024
  • *Connect the J-Link #########################################
    971 bytes (128 words) - 15:35, 8 May 2024
  • *Connect the J-Link to J3
    968 bytes (149 words) - 15:35, 8 May 2024
  • *Connect the J-Link to J4 (Pin 1 is not at the DOT on the PCB, rotate cable 180°)
    1 KB (156 words) - 15:36, 8 May 2024
  • Mainly used to set some global DLL variables to customize the normal connect procedure. ===Initialize work RAM on connect===
    3 KB (413 words) - 09:37, 14 May 2024
  • ...st found. If the next component after the core is not an CTI, the scan and connect procedure is aborted. For most v8-A/R based devices you need special connect, reset, ... sequences so just because the core is supported does not necess
    8 KB (1,262 words) - 13:54, 3 April 2024
  • * Connect the hardware to J-Link using a 20pin ribbon cable for J2
    2 KB (272 words) - 15:36, 8 May 2024
  • *Connect the J-Link : VTref=J5-2 / GND=J5-16 / SWDIO=J5-4 / SWDCLK=J5-6
    1 KB (176 words) - 15:36, 8 May 2024
  • *Connect the J-Link : VTref=J5-2 / GND=J5-16 / SWDIO=J5-4 / SWDCLK=J5-6
    1 KB (176 words) - 15:36, 8 May 2024
  • *Connect the J-Link : VTref=J5-2 / GND=J5-16 / SWDIO=J5-4 / SWDCLK=J5-6
    1 KB (176 words) - 15:36, 8 May 2024
  • *Connect the J-Link : VTref=J5-2 / GND=J5-16 / SWDIO=J5-4 / SWDCLK=J5-6
    1 KB (160 words) - 15:36, 8 May 2024
  • *Connect the J-Link : VTref=J5-2 / GND=J5-16 / SWDIO=J5-4 / SWDCLK=J5-6
    1 KB (162 words) - 15:37, 8 May 2024
  • *Connect the J-Link : VTref=J2-2 / GND=J2-16 / SWDIO=J2-4 / SWDCLK=J2-6
    1 KB (168 words) - 15:37, 8 May 2024
  • *Connect the J-Link : VTref=J5-2 / GND=J5-16 / SWDIO=J5-4 / SWDCLK=J5-6
    1,009 bytes (160 words) - 12:27, 15 February 2023
  • *Connect the J-Link : VTref=J5-2 / GND=J5-16 / SWDIO=J5-4 / SWDCLK=J5-6
    1,009 bytes (160 words) - 12:19, 15 February 2023
  • *Connect the J-Link : VTref=J5-2 / GND=J5-16 / SWDIO=J5-4 / SWDCLK=J5-6
    1,009 bytes (160 words) - 12:26, 15 February 2023
  • *Connect the J-Link : VTref=J5-2 / GND=J5-16 / SWDIO=J5-4 / SWDCLK=J5-6
    1,015 bytes (172 words) - 12:15, 15 February 2023
  • *Connect the J-Link to the SWD header (CN2) on the SMARC module
    1 KB (185 words) - 16:33, 19 December 2022
  • *Connect the J-Link : VTref=J1-2 / SWDIO=J1-4 / SWCLK=J1-6 / GND=J1-10
    938 bytes (144 words) - 20:01, 16 January 2023
  • *Connect the J-Link : VTref=J1-2 / SWDIO=J1-4 / SWCLK=J1-6 / GND=J1-10
    947 bytes (150 words) - 20:00, 16 January 2023
  • *Connect the J-Link : VTref=J1-2 / SWDIO=J1-4 / SWCLK=J1-6 / GND=J1-10
    940 bytes (144 words) - 20:04, 16 January 2023
  • *Connect the J-Link : VTref=J1-2 / GND=J1-10 / SWDIO=J1-4 / SWDCLK=J1-6
    999 bytes (154 words) - 07:56, 14 June 2023
  • * Connect the WiFi Probe to your computer via USB * Connect the WiFi Probe to your computer via USB
    8 KB (1,318 words) - 11:48, 25 April 2024
  • ...ard available that comes with an external debug header that can be used to connect an external Probe (e.g. J-Link) to it.
    878 bytes (143 words) - 15:52, 9 March 2023
  • *Connect the J-Link to J13
    824 bytes (125 words) - 14:41, 15 February 2023
  • *Connect the J-Link to J13
    824 bytes (125 words) - 14:41, 15 February 2023
  • # Supply power to the Silicon Labs evaluation board and connect it to a host PC via USB using the board's J-Link OB
    3 KB (450 words) - 15:04, 23 February 2023
  • *Connect the J-Link to the 19-pin debug connector (J31).
    492 bytes (76 words) - 12:14, 24 February 2023
  • *Connect the J-Link to J35 GND@1 Vtref@2 SWDIO@3 SWCLK@4
    971 bytes (149 words) - 10:14, 9 June 2023
  • *Connect the J-Link to the 10 pin debug connector CN12 which is located on the backs
    1 KB (216 words) - 14:50, 8 March 2023
  • *Connect the J-Link to 10-pin MCU PROG/DEBUG connector (J16)
    925 bytes (135 words) - 17:35, 15 March 2023
  • *Connect the J-Link : VTref=J1-2 / SWDIO=J1-4 / SWCLK=J1-6 / GND=J1-10
    961 bytes (149 words) - 12:48, 23 March 2023
  • *Connect the J-Link : VTref=J1-2 / SWDIO=J1-4 / SWCLK=J1-6 / GND=J1-10
    964 bytes (150 words) - 12:48, 23 March 2023
  • *Connect the J-Link : VTref=J1-2 / SWDIO=J1-4 / SWCLK=J1-6 / GND=J1-10
    985 bytes (152 words) - 13:34, 23 March 2023
  • *Connect the J-Link to CN2.
    921 bytes (138 words) - 15:55, 24 March 2023
  • *Connect the J-Link to CN5.
    931 bytes (140 words) - 07:05, 27 March 2023
  • *Connect the J-Link to CN2.
    923 bytes (138 words) - 07:43, 27 March 2023
  • *Connect the J-Link to the debug header (J13 or J20)
    1 KB (163 words) - 10:03, 27 March 2023
  • *Connect the J-Link to CN2.
    923 bytes (138 words) - 11:09, 27 March 2023
  • *Connect the J-Link to CN7.
    917 bytes (138 words) - 19:30, 27 March 2023
  • *Connect the J-Link to CN2.
    926 bytes (138 words) - 20:10, 27 March 2023
  • *Connect the J-Link to CN2.
    929 bytes (133 words) - 12:06, 16 April 2024
  • *Connect the J-Link to the JTAG connector (CN1)
    1 KB (156 words) - 11:04, 13 April 2023
  • ===Connect Specifics===
    3 KB (438 words) - 13:48, 25 July 2023
  • *Connect the J-Link to the JTAG connector (J8)
    1 KB (174 words) - 14:33, 10 May 2024
  • *Connect the J-Link to this pins:
    1 KB (159 words) - 16:55, 9 April 2024
  • ===Connect===
    2 KB (279 words) - 11:22, 10 October 2023
  • * A way to connect to the 10 pin debug connector of the Arduino Giga R1 board e.g. a [https:// '''Note:''' Due to some issues with the Arduino Bootloader it is necessary to connect via the J-Link Commander twice as the first try will fail.
    4 KB (632 words) - 14:25, 10 May 2024
  • ...are from anywhere for software development and debugging. Users can simply connect to one of the boards in the test farm over the network, control power, down ...access to the same hardware in different configurations, or allow users to connect to a variety of completely different boards.
    3 KB (521 words) - 22:52, 23 February 2024
  • *Connect the J-Link to P9.
    472 bytes (82 words) - 08:24, 3 May 2023
  • *Connect the J-Link to P9.
    472 bytes (82 words) - 08:26, 3 May 2023
  • *On connect, the reset source of the watchdog will be disabled, so it keeps running, bu
    1 KB (202 words) - 11:23, 10 October 2023
  • ===Connect=== A device specific connect sequence is executed which supports:
    3 KB (408 words) - 15:58, 19 February 2024
  • *Connect the J-Link to J4
    879 bytes (138 words) - 09:53, 17 May 2023
  • *Connect the J-Link to J11, J6 hast to set in order to disable MCU-Link on the PCB a
    951 bytes (150 words) - 10:53, 22 May 2023
  • # Connect J-Link to a PC via USB
    1 KB (166 words) - 11:17, 12 June 2023
  • However, a connect to E31xx devices will initialize 128KB at 0x500000 (1MB at 0x400000 for E31
    865 bytes (129 words) - 13:54, 24 May 2023
  • However, a connect to E32xx devices will initialize 512KB at 0x500000 (1MB at 0x400000 for E32
    1 KB (163 words) - 13:54, 24 May 2023
  • However, a connect to E33xx devices will initialize 1MB at 0x400000.
    1 KB (158 words) - 13:54, 24 May 2023
  • However, a connect to CPU 0 of E34xx devices will initialize 1MB at 0x400000.
    1,017 bytes (163 words) - 14:41, 7 June 2023
  • *Connect the J-Link to the JTAG header (J301)
    657 bytes (103 words) - 13:54, 24 May 2023
  • However, a connect to CPU 0 of E36xx devices will initialize 1MB at 0x400000.
    1 KB (184 words) - 14:41, 7 June 2023
  • However, a connect to D32xx devices will initialize 1MB at 0x400000.
    835 bytes (124 words) - 13:21, 30 May 2023
  • ...aits for TCK changes to be echoed correctly before making further changes. Connect to RTCK if available, otherwise to GND.
    17 KB (2,764 words) - 11:02, 4 January 2024
  • *Connect the J-Link to P4 *Connect JP3 to GND (middle position)
    941 bytes (152 words) - 09:37, 14 June 2023
  • *Connect the J-Link to J400.
    1 KB (165 words) - 09:43, 14 June 2023
  • *Connect the J-Link to J400.
    1 KB (164 words) - 09:52, 14 June 2023
  • *Connect the J-Link to J400.
    1 KB (156 words) - 09:52, 14 June 2023
  • * Connect your board to a J-Link as explained above and test the connection with J-Li
    4 KB (657 words) - 14:25, 10 May 2024
  • *Connect the J-Link to CN5 using the [https://www.segger.com/products/debug-probes/j
    958 bytes (139 words) - 10:12, 23 April 2024
  • *Connect the J-Link to CN12.
    819 bytes (129 words) - 13:42, 28 June 2023
  • *Connect the J-Link to CN3.
    848 bytes (134 words) - 15:50, 28 June 2023
  • *Connect the J-Link to CN11.
    805 bytes (136 words) - 13:20, 28 June 2023
  • *Connect the J-Link to CN9.
    790 bytes (123 words) - 13:14, 28 June 2023
  • *Connect the J-Link to CN4.
    834 bytes (131 words) - 13:31, 28 June 2023
  • *Connect the J-Link to the following Pins:
    949 bytes (145 words) - 16:05, 29 June 2023
  • *Connect the J-Link to CN3-8(GND) CN3-9(SWDIO) CN3-11(SWDCLK) CN3-12(VTref) CN3-14(R
    986 bytes (162 words) - 17:30, 2 April 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    2 KB (199 words) - 13:00, 18 March 2024
  • * Connect the board with jumping wires to your J-Link (see table below)<br>For inform
    2 KB (239 words) - 16:37, 3 August 2023
  • *Connect the J-Link to CN5 via https://www.segger.com/products/debug-probes/j-link/a
    4 KB (651 words) - 14:51, 13 May 2024
  • Once a modules' UART Port is enabled, a TCP/IP client can connect to it by opening a raw connection to Flasher Hub's IP address and the respe
    4 KB (599 words) - 16:12, 6 May 2024
  • # Connect Flasher Hub to power supply via the ''POWER'' connector # Connect Flasher Hub to LAN via the ''LAN'' connector
    15 KB (2,345 words) - 16:02, 6 May 2024
  • # Connect to the Flasher Hub Web interface via a browser.
    5 KB (756 words) - 16:03, 6 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    1 KB (163 words) - 15:34, 7 May 2024
  • ...ot in a script file or empty (simply returns 0), this has no effect on the connect sequence of J-Link. ===JTAG specific connect===
    9 KB (950 words) - 12:06, 22 April 2024
  • *Connect the J-Link to J15.
    867 bytes (138 words) - 12:13, 19 March 2024
  • During connect the M4 is set to execute an endless loop at 0x1FFE0000 (TCM RAM). ===Connect===
    1 KB (210 words) - 10:28, 8 April 2024
  • During connect the M7 is set to execute an endless loop at 0x00000000 (TCM RAM). ===Connect===
    2 KB (232 words) - 10:36, 3 May 2024
  • During connect the M7 is set to execute an endless loop at 0x00000000 (TCM RAM). ===Connect===
    2 KB (293 words) - 10:29, 8 April 2024
  • ===Connect===
    2 KB (330 words) - 16:08, 5 April 2024
  • ===Connect===
    2 KB (317 words) - 12:13, 5 April 2024
  • *Connect the J-Link to CN3-8(GND) CN3-9(SWDIO) CN3-11(SWDCLK) CN3-12(VTref) CN3-14(R
    974 bytes (157 words) - 17:26, 2 April 2024
  • *Connect the J-Link to this pins: [[File:GigaDevice_GD32303C-START_GD32F303CGT6.connect.png|400px]]
    1 KB (159 words) - 14:23, 3 April 2024
  • *Connect the J-Link to the JTAG header (JP1) [[File:GigaDevice_GD32303E-EVAL_GD32F303ZE.connect.png|400px]]
    890 bytes (135 words) - 15:11, 2 April 2024
  • *Connect the J-Link to this pins:
    1 KB (159 words) - 14:24, 3 April 2024
  • *Connect the J-Link to the JTAG header (JP1)
    890 bytes (135 words) - 17:36, 3 April 2024
  • *Connect the J-Link to this pins:
    1 KB (159 words) - 11:47, 5 April 2024
  • *Connect the J-Link to JTAG connector (J902). *Connect the onboard USB-UART debug interface to host computer (J901).
    1 KB (223 words) - 09:33, 5 April 2024
  • *Connect the J-Link to JTAG connector (J902). *Connect the onboard USB-UART debug interface to host computer (J901).
    1 KB (223 words) - 09:43, 5 April 2024
  • *Connect the J-Link to JTAG connector (J24). *Connect the onboard USB-UART debug interface to host computer (J23).
    1 KB (223 words) - 09:51, 5 April 2024
  • *Connect the J-Link to JTAG connector (J18). *Connect the onboard USB-UART debug interface to host computer (J19).
    1 KB (217 words) - 10:31, 5 April 2024
  • *Connect the J-Link to JTAG connector (J4). *Connect the onboard USB-UART debug interface to host computer (J11).
    1 KB (214 words) - 10:31, 5 April 2024
  • *Connect the J-Link to the JTAG header (JP1)
    890 bytes (135 words) - 14:32, 5 April 2024
  • *Connect the J-Link to the JTAG header (JP1)...
    973 bytes (135 words) - 15:12, 5 April 2024
  • *Connect the J-Link to this pins:
    1 KB (159 words) - 15:50, 5 April 2024
  • *Connect the J-Link to the JTAG header (JP1)
    890 bytes (135 words) - 16:04, 5 April 2024
  • *Connect the J-Link to JTAG connector (J11). *Connect the onboard USB-UART debug interface to host computer (J18).
    1 KB (214 words) - 16:28, 5 April 2024
  • *Connect the J-Link to this pins:
    1 KB (159 words) - 16:55, 5 April 2024
  • *Connect the J-Link to JTAG connector (J401). *Connect the onboard USB-UART debug interface to host computer (J1401).
    1 KB (224 words) - 16:46, 5 April 2024
  • * Connect the J-Link to the SWD header (XDS110).
    1 KB (168 words) - 11:00, 10 April 2024
  • * Connect the J-Link to the SWD header (ETM1).
    5 KB (743 words) - 16:50, 7 May 2024
  • * Connect the J-Link to the SWD header (CN5).
    5 KB (749 words) - 16:55, 7 May 2024
  • ===Connect=== *On Connect, the RAM is initialized.
    1 KB (146 words) - 17:47, 18 March 2024
  • === Connect under reset === In case that J-Link fails to connect to the device (usually caused by a low-power state of the MCU),
    6 KB (995 words) - 12:56, 18 March 2024
  • * Connect the board with jumping wires to your J-Link (see table below)<br>For inform
    2 KB (259 words) - 15:05, 11 August 2023
  • ...trol|Flasher Control]] || Command-line tool to connect to the Flasher's command-line interface via USB. After installation, connect Flasher to the host PC via USB or Ethernet.
    155 KB (23,284 words) - 08:54, 3 April 2024
  • * A way to connect to the 10 pin debug connector of the Arduino Uno R4 Minima board e.g. a [ht * Connect your board to a J-Link as explained above and test the connection with J-Li
    4 KB (594 words) - 14:26, 10 May 2024
  • ** Connect JLINK to P2 (SWD) ** Connect JLINK to J19 (JTAG)
    1 KB (183 words) - 09:56, 24 October 2023
  • *Connect the J-Link to this pins:
    1 KB (174 words) - 14:27, 10 May 2024
  • *Connect the J-Link to the SWD header (CN3)
    1,022 bytes (155 words) - 13:39, 7 September 2023
  • *Connect the J-Link to the SWD header (CN5)
    1,023 bytes (150 words) - 13:37, 7 September 2023
  • *Connect the J-Link to the SWD header (P2)
    990 bytes (146 words) - 13:52, 7 September 2023
  • ...will prevent a debug connection via debug pins, thus preventing J-Link to connect.
    3 KB (506 words) - 15:11, 20 September 2023
  • *Connect the J-Link to J7 using the [https://www.segger.com/products/debug-probes/j-
    1,006 bytes (149 words) - 10:40, 20 September 2023
  • == How to connect to Vivado == If no command line options are passed, the XVCD Server will connect to the available J-Link.
    4 KB (576 words) - 17:11, 7 September 2023
  • *Connect the J-Link to P3 VTref@P3.1, GND@ P3.2, SWDIO@P3.4, SWCLK@P3.5.
    945 bytes (141 words) - 15:52, 14 September 2023
  • *Connect the J-Link to the JTAG connector (J2)
    648 bytes (100 words) - 11:15, 13 September 2023
  • *Connect the J-Link to CORTEX DEBUg.
    965 bytes (144 words) - 11:33, 14 September 2023
  • *Connect the J-Link to J25
    912 bytes (142 words) - 15:07, 20 September 2023
  • *Connect the J-Link to J302
    838 bytes (129 words) - 15:20, 20 September 2023
  • ...ink software will initialize 0x6400 bytes of SRAM at address 0x20000000 on connect.<br> ..., the J-Link software will popup a request for an unlock via mass-erase on connect.
    3 KB (494 words) - 14:34, 23 October 2023
  • ...ult, the J-Link initializes RAM regions which are required for the initial connect to the target only. For the RT1180 series, the initialized regions depend o ...0x20000000 (128 KB) which is used as work RAM during flash programming on connect.
    2 KB (343 words) - 11:52, 6 December 2023
  • *Connect the J-Link to J37
    505 bytes (77 words) - 08:41, 22 September 2023
  • *Connect the J-Link to the JTAG connector (J8)
    745 bytes (112 words) - 14:34, 10 May 2024
  • *Connect the J-Link to J88.
    899 bytes (141 words) - 08:52, 28 September 2023
  • *Connect the J-Link to J18.
    945 bytes (140 words) - 10:17, 28 September 2023
  • | 1x Flasher Hub<ref name="hub-disclaimer">It is not recommended to directly connect Flasher to Hub, please always use a powered USB-Hub.</ref> <br/> 4x Flasher ...SB-3) occupy up to 3 device endpoints. Therefore, it may be a challenge to connect all 24 flashers and the fail-save USB drive. If you have such problems, ple
    4 KB (603 words) - 16:59, 9 November 2023
  • ...=Don't connect Flasher Compact modules directly to the Flasher Hub. Always connect Flasher Compact modules to the Flasher Hub via powered USB hubs.}} ...finished booting (i.e. after the green LED has stopped flashing), you can connect to the Flasher Hub's web interface by pointing your web browser to
    67 KB (9,981 words) - 17:19, 3 November 2023
  • ===Connect=== No device specific initialization sequence is executed on connect. The J-Link SW assumes that the selected core is enabled / attach is possib
    5 KB (874 words) - 14:42, 11 January 2024
  • *Connect the J-Link to the board via JTAG MIPI connector (non standard adapter is re
    2 KB (234 words) - 11:35, 25 October 2023
  • J-Link supports native debug unlock via mass erase during connect.
    2 KB (328 words) - 10:43, 10 October 2023
  • === Connect via On Board J-Link === * Connect the board to your PC via the mini USB connector.
    1 KB (179 words) - 15:19, 10 October 2023
  • ...hable USB output. This can either directly supply power to the hardware or connect to a switching relay, allowing external control of the hardware's power. Th
    5 KB (792 words) - 16:00, 20 October 2023
  • GD32H7 devices have ECC RAM which can be disabled. However, a connect to GD32H7 devices will initialize 16KB at 0x20000000.
    724 bytes (102 words) - 09:42, 2 November 2023
  • ===Connect=== The connect sequence of PMG1 devices is very time critical and is performed from the J-
    3 KB (403 words) - 09:44, 14 May 2024
  • *Connect the J-Link to this pins:
    1 KB (168 words) - 12:42, 13 May 2024
  • ===Connect=== *The J-Link determines the security state as part of the connect sequence. If a secured device is detected, an un-secure is offered via dial
    1 KB (176 words) - 14:49, 29 November 2023
  • *Connect the J-Link to JP1.
    920 bytes (140 words) - 17:15, 25 October 2023
  • *Connect the J-Link to J11, J6 hast to set in order to disable MCU-Link on the PCB a
    951 bytes (150 words) - 16:18, 15 December 2023
  • *Connect the J-Link to ...... '''[PICTURE OF CONNECT]'''
    865 bytes (131 words) - 14:27, 6 November 2023
  • *Connect the J-Link to the debug connector (P18) [[File:nrf9161-connect.png|400px]]
    1 KB (158 words) - 14:14, 7 November 2023
  • *Connect the J-Link to the SWD header (J9) using single wires
    695 bytes (109 words) - 14:21, 10 May 2024
  • ...but has the disadvantage that the thread calling connect() is blocked and connect exit itself during the timeout counts down, in case an application close re r = SYS_SOCKET_Connect(hSock, 0x7F000001, 19021); // Connect to 127.0.0.1, port 19021
    6 KB (863 words) - 09:31, 15 January 2024
  • * Connect NRST, SWDIO, SWCLK wires from J-Link adapter to the right side(labeled as T * Connect GND and VTREF wires to the J4 connector.
    2 KB (289 words) - 18:04, 30 November 2023
  • ===Connect===
    3 KB (404 words) - 09:39, 15 April 2024
  • Whenever you want to program a new device, you have to connect it to the Flasher according to the device's corresponding wiring diagram.
    7 KB (1,050 words) - 15:04, 19 December 2023
  • *Connect the J-Link to P1.
    472 bytes (79 words) - 19:50, 11 December 2023
  • *Connect the J-Link to CORTEX DEBUG connector (J300).
    1 KB (157 words) - 16:49, 13 December 2023
  • *Connect the J-Link to CORTEX DEBUG connector (J300).
    1 KB (157 words) - 16:49, 13 December 2023
  • *Connect the J-Link to J23, J22 hast to set in order to disable MCU-Link on the PCB
    905 bytes (138 words) - 16:19, 15 December 2023
  • *Connect the J-Link to J4.
    825 bytes (126 words) - 16:19, 15 December 2023
  • For information on how to connect to a Flasher connected via Ethernet to a network please refer to [[UM08022_
    4 KB (683 words) - 18:30, 15 December 2023
  • ===Connect===
    786 bytes (94 words) - 12:40, 27 December 2023
  • *Connect the J-Link to J18:
    988 bytes (148 words) - 10:56, 22 February 2024
  • *Connect the J-Link to J18:
    986 bytes (148 words) - 10:52, 22 February 2024
  • ===Connect===
    784 bytes (94 words) - 13:14, 27 December 2023
  • *Connect the J-Link to J24, JP8 hast to set in order to disable MCU-Link on the PCB
    940 bytes (144 words) - 11:08, 13 March 2024
  • *Connect the J-Link to J18.
    908 bytes (138 words) - 13:02, 10 January 2024
  • *Connect the J-Link to: VTref@J9.1 GND@J9.4 TCK@Jx. TDI@Jx. TDO@Jx. RESET@Jx. .
    977 bytes (151 words) - 11:13, 15 January 2024
  • *Connect the J-Link to this pins:
    1 KB (173 words) - 14:28, 10 May 2024
  • *Connect the J-Link to this pins:
    1 KB (172 words) - 14:28, 10 May 2024
  • *Connect the J-Link to this pins:
    1 KB (179 words) - 14:27, 10 May 2024
  • *Connect the J-Link to this pins:
    1 KB (174 words) - 14:27, 10 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    1 KB (126 words) - 12:01, 12 March 2024
  • *Connect the J-Link to this pins:
    1 KB (164 words) - 14:27, 10 May 2024
  • *Connect the J-Link to this pins:
    1 KB (176 words) - 14:27, 10 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    2 KB (214 words) - 13:02, 18 March 2024
  • *Connect the J-Link to this pins:
    1 KB (180 words) - 14:27, 10 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    2 KB (318 words) - 13:03, 18 March 2024
  • *Connect the J-Link to this pins:
    1 KB (178 words) - 14:26, 10 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    896 bytes (104 words) - 12:59, 18 March 2024
  • *Connect the J-Link to this pins:
    1 KB (168 words) - 16:44, 8 February 2024
  • *Connect the J-Link to the JTAG connector (IDC1)
    643 bytes (99 words) - 08:54, 7 February 2024
  • *Connect the J-Link to the JTAG header (J14)
    633 bytes (100 words) - 09:35, 7 February 2024
  • *Connect the J-Link to this pins:
    1 KB (178 words) - 14:27, 10 May 2024
  • *Connect the J-Link to this pins:
    1 KB (172 words) - 14:27, 10 May 2024
  • *Connect the J-Link to this pins:
    1 KB (178 words) - 14:26, 10 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    1 KB (192 words) - 13:04, 18 March 2024
  • *Connect the J-Link to J12, JP8 hast to set in order to disable MCU-Link on the PCB
    939 bytes (141 words) - 13:48, 9 February 2024
  • === Connect under reset === In case that J-Link fails to connect to the device (usually caused by a low-power state of the MCU),
    8 KB (1,241 words) - 07:22, 8 May 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    2 KB (267 words) - 09:27, 25 April 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    2 KB (264 words) - 11:32, 27 February 2024
  • *Connect the J-Link to this pins:
    1 KB (166 words) - 16:17, 27 February 2024
  • *Connect the J-Link to this pins:
    1 KB (157 words) - 16:52, 27 February 2024
  • *Connect the J-Link to this pins:
    1 KB (158 words) - 14:25, 3 April 2024
  • *Connect the J-Link to this pins:
    1 KB (164 words) - 18:29, 27 February 2024
  • *Connect the J-Link to the JTAG header (JP3)
    888 bytes (135 words) - 14:26, 3 April 2024
  • ===Connect=== *Connect under reset is supported
    1 KB (161 words) - 10:53, 28 February 2024
  • *Connect the J-Link to this pins:
    1 KB (163 words) - 13:43, 2 April 2024
  • ===Connect=== *Connect under reset is supported
    1 KB (156 words) - 11:07, 28 February 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    1 KB (148 words) - 17:13, 28 February 2024
  • *Attach is not supported because the J-Link initializes the device on connect
    4 KB (485 words) - 16:32, 14 March 2024
  • ===Connect=== *On Connect, protection level is checked. For further information regarding this, pleas
    2 KB (272 words) - 09:35, 29 February 2024
  • An example configuration to connect to the terminal of module #1 using PuTTY looks as follows:<br>
    2 KB (340 words) - 15:54, 6 May 2024
  • The Flasher Hub supports multiple interfaces to connect to the Flasher Hub and access its ASCII terminal.
    26 KB (3,387 words) - 16:14, 6 May 2024